1.5T Superconducting MRI Scanner — £399,000
Hospital-grade diagnostic imaging at a fraction of major OEM pricing. Superconducting magnet technology, 50cm whole-body field of view, and a complete 5-coil package included.
Manufactured by Shenzhen ANKE · ANALOGIC RF subsystem · Worldwide delivery

A Complete Clinical MRI Platform
The SXR 1.5T Superconducting MRI System is a high-field diagnostic imaging platform featuring ANKE proprietary A-Winding magnet technology and ANALOGIC RF subsystems. This clinical-grade scanner utilises superconducting magnet technology with active shielding to deliver high-resolution imaging across a 50cm × 50cm × 50cm field of view.
Suitable for whole-body clinical applications including bariatric patients, the system integrates a 20kW RF amplifier, high-slew-rate gradients (150 mT/m/ms), and a modular 8-channel spectrometer architecture expandable to 16 channels.
The A-Shielding technology reduces eddy currents by 80%, enabling high-resolution sequences while minimising acoustic noise compared to conventional designs.
Technical Specifications
Detailed system parameters for clinical and procurement evaluation
| Magnet System | |
|---|---|
| Field Strength | 1.5 Tesla (Superconducting, helium-cooled) |
| Magnet Technology | A-Winding technology (ANKE proprietary) |
| Active Shielding | A-Shielding (80% eddy current reduction) |
| Field of View | 50cm × 50cm × 50cm (X, Y, Z) |
| Shimming | Dynamic shimming (active compensation) |
| Cryogen | Liquid helium (refill required) |
| Spectrometer & RF | |
|---|---|
| Spectrometer | 8-channel (expandable to 16) |
| RF Amplifier | 20kW output (ANALOGIC) |
| RF Characteristics | High stability, strong signal output |
| Modularity | Modular design for simplified maintenance |
| Gradient System | |
|---|---|
| Gradient Strength | 40 mT/m |
| Slew Rate | 150 mT/m/ms |
| Eddy Current Compensation | Integrated compensation technology |
| Acoustic Noise | Reduced through A-Shielding design |
| Workstation & Data | |
|---|---|
| Workstation | DELL MRI-dedicated workstation |
| Data Protection | DIS (Data Protection System) |
| Software | ANKE MRI software platform |
| Receiver Coils | |
|---|---|
| Head coil | 8-channel |
| Neck-Chest coil | 8-channel |
| Body coil | 8-channel |
| Knee coil | 8-channel |
| Multi-function soft coil | 4-channel (flexible positioning) |
Key System Features
What sets this MRI system apart
A-Winding Magnet Technology
ANKE's proprietary winding configuration ensures superior magnetic field homogeneity across the 50cm FOV. Accommodates larger patients while maintaining diagnostic image quality throughout the entire scan range.
A-Shielding Active Shielding
Reduces eddy currents by 80% compared to conventional designs. Delivers high-resolution image acquisition with minimal artefacts, reduced acoustic noise, and faster gradient switching without image degradation.
High-Performance Gradients
40 mT/m strength and 150 mT/m/ms slew rate supports advanced echoplanar imaging for fMRI, high b-value DWI, rapid cardiac imaging, and high-resolution musculoskeletal protocols.
ANALOGIC RF Subsystem
The 20kW RF amplifier from ANALOGIC provides strong, stable RF transmission for large FOV imaging with consistent flip angle delivery across the full 50cm volume.
Expandable Channel Architecture
Standard 8-channel spectrometer with upgrade path to 16 channels. Enables parallel imaging for faster scans and future coil upgrades without replacing hardware.
Dynamic Shimming
Real-time dynamic shimming automatically compensates for field inhomogeneities caused by patient anatomy, ensuring consistent fat suppression and spectral quality throughout examinations.
Clinical Applications
Versatile diagnostic capabilities across medical specialities
High-resolution brain imaging, functional MRI (fMRI), diffusion tensor imaging (DTI), spectroscopy. The 1.5T field strength and high-slew-rate gradients enable detailed assessment of stroke, tumours, white matter diseases, and neurodegenerative conditions.
Cine imaging, myocardial perfusion studies, delayed enhancement for viability assessment. The system supports comprehensive cardiac evaluation including valve assessment, congenital heart disease, and cardiomyopathy characterisation.
Liver, kidney, and abdominal angiography with full 50cm FOV coverage. Whole-body staging, lesion characterisation, and treatment response monitoring. The large FOV accommodates bariatric patients up to 250kg+.
High-resolution joint imaging for knee, shoulder, hip, ankle, and spine assessment. The 40 mT/m gradients and 8-channel dedicated knee coil deliver exceptional cartilage, ligament, and meniscal visualisation.
Suitable for functional MRI neuroscience research, diffusion studies with high b-value capabilities, MR spectroscopy, and standardised multi-centre clinical trial platforms.
When configured with appropriate coils, the system supports large animal imaging (equine, bovine) and small animal research applications.
How Our MRI Pricing Compares
The same clinical-grade technology. A fundamentally different price point.
| Feature | Major OEM (Philips, Siemens, GE) | BEST VALUESXR Lab Equipment |
|---|---|---|
| 1.5T Superconducting Magnet | ||
| 40 mT/m Gradient Strength | ||
| 8+ Channel Spectrometer | 8ch (expandable to 16) | |
| Whole-Body 50cm FOV | ||
| Dynamic Shimming | ||
| Active Shielding | 80% eddy current reduction | |
| Standard Coil Package | 2-3 coils | 5 coils included |
| Typical Price | £800,000 – £1,200,000+ | £200,000 |
What's Included in Your Purchase
Everything you need to start scanning — no hidden costs
Included
- 1.5T Superconducting MRI Scanner (complete system)
- 8-Channel Head Coil
- 8-Channel Neck-Chest Coil
- 8-Channel Body Coil
- 8-Channel Knee Coil
- 4-Channel Multi-Function Soft Coil
- DELL MRI-Dedicated Workstation
- ANKE MRI Software Platform
- DIS Data Protection System
- System documentation and technical manuals
- Site planning guidance and consultation
Not Included (Transparency)
- Faraday cage / RF shielding (typically £30,000–£80,000)
- Liquid helium initial fill (approx. £5,000–£15,000)
- Quench vent installation (site-specific)
- 3-phase electrical supply installation
- Chilled water supply for gradient cooling
- Physical installation and magnet ramp-up
- Service/maintenance contract (recommended)
Site Planning & Infrastructure Requirements
What your facility needs to install a 1.5T MRI system
| Siting Requirements | |
|---|---|
| Magnet Weight | 4,000 – 7,000 kg |
| Floor Loading | 10,000+ kg concentrated load |
| Minimum Room Size | 50m² (scan + equipment + console) |
| Ceiling Height | 2.8m minimum |
| Quench Vent | Mandatory safety venting required |
| RF Shielding | Full Faraday cage required |
| Magnetic Shielding | Active shielding included; 5-gauss line planning required |
| Utility Requirements | |
|---|---|
| Cryogen Supply | Liquid helium fill line and gas recovery |
| Power | 3-phase 400V/480V (generator backup recommended) |
| Cooling | Chilled water for gradients (heat exchanger) |
| HVAC | Temperature stability ±3°C, humidity 40-60% |
| Maintenance | |
|---|---|
| Helium Management | Boil-off monitoring (0.01-0.1% per day) |
| Cold Head | Cryocooler replacement every 10,000-30,000 hours |
| Service Contract | Recommended for superconducting systems |
Regulatory & Compliance Information
Important information for UK and international buyers
CE / UKCA Marking
Verify CE marking (or UKCA post-Brexit) status for your specific unit. SXR provides full documentation on system provenance and certification status. We recommend confirming compliance requirements with your local regulatory body before purchase.
MHRA Registration (UK)
For deployment in UK clinical environments, the device should appear on the UK medical device register. SXR provides all necessary documentation to support your MHRA registration process.
ISO 13485 Quality Management
The manufacturing facility operates under ISO 13485 quality management standards for medical devices. Full quality documentation is available upon request.
Safety & Site Licensing
MRI uses magnetic fields and radio waves (non-ionising). ARSAC certification may apply for site licensing. Your facility's radiation protection advisor can guide specific requirements.
SXR Lab Equipment recommends that all buyers conduct their own due diligence regarding regulatory compliance for their specific jurisdiction and intended use. We provide full transparency on system documentation and are happy to answer any compliance-related questions.
Frequently Asked Questions
Common questions from MRI system buyers